The MVI56 IEC 60870-5-101 Slave Network Interface Module is the fastest and easiest way to add IEC 60870-5-101 protocol interface connectivity for the ControlLogix platform. The module has two powerful and highly configurable IEC 60870-5-101 Slave ports, allowing the many SCADA and field devices supporting the IEC protocol to be integrated into the ControlLogix platform. The MVI56-101S is designed to address applications where a host system using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE). These features allow the MVI56-101S module to send a report to the processor without being polled, providing real time data transmission in critical situations.
The MVI56-101S Edition 2 module is the best way to add IEC 60870-5-101 protocol interface support to the ControlLogix platform. This module has two powerful and highly-configurable IEC 60870-5-101 Slave serial ports, allowing many SCADA and field devices using this IEC protocol to be integrated into the ControlLogix platform.
The module acts as an input/output module between the IEC 60870-5-101 telecontrol network and the Rockwell Automation ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the network. A 5000-word register space in the module exchanges data between the processor and the telecontrol network.
Specification |
Description |
Backplane Current Load |
800 mA @ 5.1 VDC |
Operating Temperature |
32° F to 140° F (0° C to 60° C) |
Storage Temperature |
-40° F to 185° F (-40° C to 85° C) |
Shock |
30 g Operational |
Vibration |
5 g from 10 to 150 Hz |
Relative Humidity |
5% to 95% (without condensation) |
LED Indicators |
Module Status |
Debug/Configuration port (CFG) |
|
CFG Port (CFG) |
RJ45 (DB-9M with supplied cable) |
Application ports (PRT1 & PRT2) Full hardware handshaking control, providing radio, modem and multi-drop support |
|
Software configurable communication parameters |
Baud rate: 110 to 115,200 baud, depending on protocol RS-232, 485 and 422 Parity: none, odd or even Data bits: 5, 6, 7, or 8 Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds |
App Ports (P1,P2) (Serial modules) |
RJ45 (DB-9M with supplied cable) RS-232 handshaking configurable 500 V Optical isolation from backplane |
Shipped with Unit |
RJ45 to DB-9M cables for each port 6-foot RS-232 configuration cable |
ATEX Letter of Conformity | 79.81 kB | Last Modified 05/12/2022 |
CB Safety | 41.99 kB | Last Modified 02/26/2020 |
Declaration of Conformity (RoHS/CE) | 137.73 kB | Last Modified 05/20/2022 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1.92 MB | Last Modified 07/10/2020 |
Korean KC Registration | 616.34 kB | Last Modified 03/13/2020 |
UL/cUL; Class 1, Div 2 | 1.12 MB | Last Modified 02/27/2019 |
UL/cUL; Class 1, Div 2 (Canada) | 1.14 MB | Last Modified 02/27/2019 |
Declaration of REACH Compliance | 133.82 kB | Last Modified 05/20/2022 |