MVI56-Serial Picture

IEC 60870-5-101 Slave Network Interface Module for ControlLogix

MVI56-101S

Discontinued: No new product for sale. More Info

The MVI56 IEC 60870-5-101 Slave Network Interface Module is the fastest and easiest way to add IEC 60870-5-101 protocol interface connectivity for the ControlLogix platform. The module has two powerful and highly configurable IEC 60870-5-101 Slave ports, allowing the many SCADA and field devices supporting the IEC protocol to be integrated into the ControlLogix platform. The MVI56-101S is designed to address applications where a host system using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE). These features allow the MVI56-101S module to send a report to the processor without being polled, providing real time data transmission in critical situations.

Features and Benefits

The MVI56-101S Edition 2 module is the best way to add IEC 60870-5-101 protocol interface support to the ControlLogix platform. This module has two powerful and highly-configurable IEC 60870-5-101 Slave serial ports, allowing many SCADA and field devices using this IEC protocol to be integrated into the ControlLogix platform.

The module acts as an input/output module between the IEC 60870-5-101 telecontrol network and the Rockwell Automation ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the network. A 5000-word register space in the module exchanges data between the processor and the telecontrol network.

Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Local or remote rack

Hardware

Specification

Description

Backplane Current Load

800 mA @ 5.1 VDC
3 mA @ 24 VDC

Operating Temperature

32° F to 140° F (0° C to 60° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Shock

30 g Operational
50 g non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (without condensation)

LED Indicators

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Debug/Configuration port (CFG)

CFG Port (CFG)

RJ45 (DB-9M with supplied cable)
RS-232 only

Application ports (PRT1 & PRT2)

Full hardware handshaking control, providing radio, modem and multi-drop support

Software configurable communication parameters

Baud rate: 110 to 115,200 baud, depending on protocol

RS-232, 485 and 422

Parity: none, odd or even

Data bits: 5, 6, 7, or 8

Stop bits: 1 or 2

RTS on/off delay: 0 to 65535 milliseconds

App Ports (P1,P2) (Serial modules)

RJ45 (DB-9M with supplied cable)

RS-232 handshaking configurable

500 V Optical isolation from backplane

Shipped with Unit

RJ45 to DB-9M cables for each port

6-foot RS-232 configuration cable

Certifications

ATEX Letter of Conformity 79.81 kB Last Modified 05/12/2022
CB Safety 41.99 kB Last Modified 02/26/2020
Declaration of Conformity (RoHS/CE) 137.73 kB Last Modified 05/20/2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB Last Modified 07/10/2020
Korean KC Registration 616.34 kB Last Modified 03/13/2020
UL/cUL; Class 1, Div 2 1.12 MB Last Modified 02/27/2019
UL/cUL; Class 1, Div 2 (Canada) 1.14 MB Last Modified 02/27/2019