Features and Benefits

The MVI56-LTQ module acts as an input/output module between the Limitorque valve network and the ControlLogix processor. The data transfer from the ControlLogix processor is asynchronous from the actions on the network. The 1500-word register space in the module transfers the valve information from the module to the processor. Ladder logic is responsible for control of the valves. Data transferred from the processor to the module instructs the module to execute commands to valves on the Limitorque network.

Applications

Industries and services that benefit from this integration include Aerospace, Chemical, Food/Beverage, Industrial Gases, Oil & Gas production, exploration, processing and refining, Mining, Pharmaceutical, Power, Pulp & Paper, Water/Wastewater.

Specifications

  • Implements Limitorque's Port A/B polling scheme using both ports on the LTQ module
  • RS-232 or RS-485 communications (jumper selectable)
  •  Software configuration (from processor ladder logic)
     - Baud rate: 1,200 TO 38,400
     - Message response timeout
     - Number of active slaves: 1 to 150
     - Last state on comm fail
     - Network polling scheme (looped, port 1 only, port 2 only)
    - Active slave table: bit mapped up to 150 slaves)
  •  Supported commands
     - Continuously poll: read registers 40008 - 40013
     - Valve position
     - Status and fault registers
     -Digital outputs and digital
     - Inputs registers1 and 2
    - Communication error code and comm counter)
  •  Commands
    - Open, stop, close, initiate network ESD, terminate network ESD, engage contactors 1 - 6, disengage contactors 1 - 6, valve position (0 - 100%))
  • Support for the storage and transfer of up to 150 valves to the ControlLogix processor's controller tags
  • Emulates Limitorque's Port A/B polling scheme using both ports on the module
  •  Supports the following valves
     
    • MX/DDC Modbus
    • UEC-3-DDC Modbus
    • DDC-100M I/O module
    • DDC-100M field unit
    • Valvcon IVO (unit in multi-drop mode only)
  •  Software configuration
     
    • Baud rate: 1200 to 115200
    • Message response timeout
    • Number of active slaves
    • Last state on communication failure for valve data
    • Network polling scheme
    • Active slave table (bit mapped)
    • Use of CTS module line option
    • Backplane failure affect on communication port availability
  •  Support command
     
    • Continuously polled
    • Read registers 40008 to 40013, optional 40055 or 40006/40007
    • Commands: open, stop, close, initiate network ESD, terminate network ESD, engage contactors 1 to 6, disengage contactors 1 to 6, position valve (0 to 100%)
  •  Data returned to the processor for each valve
     
    • Valve position
    • Status register
    • Fault register
    • Digital outputs
    • Digital inputs registers 1 and 2
    • Communication error code
    • Communication poll counter
    • Special polled registers

Hardware

Specification

Description

Backplane Current Load

800 mA @ 5.1 VDC
3 mA @ 24 VDC

Operating Temperature

32° F to 140° F (0° C to 60° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Shock

30 g Operational
50 g non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (without condensation)

LED Indicators

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Debug/Configuration port (CFG)

CFG Port (CFG)

RJ45 (DB-9M with supplied cable)
RS-232 only

Application ports (PRT1 & PRT2)

Full hardware handshaking control, providing radio, modem and multi-drop support

Software configurable communication parameters

Baud rate: 110 to 115,200 baud, depending on protocol

RS-232, 485 and 422

Parity: none, odd or even

Data bits: 5, 6, 7, or 8

Stop bits: 1 or 2

RTS on/off delay: 0 to 65535 milliseconds

App Ports (P1,P2) (Serial modules)

RJ45 (DB-9M with supplied cable)

RS-232 handshaking configurable

500 V Optical isolation from backplane

Shipped with Unit

RJ45 to DB-9M cables for each port

6-foot RS-232 configuration cable

Certifications

ATEX Letter of Conformity 79.81 kB Last Modified 05/12/2022
CB Safety 41.99 kB Last Modified 02/26/2020
Declaration of Conformity (RoHS/CE) 137.73 kB Last Modified 05/20/2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB Last Modified 07/10/2020
Korean KC Registration 616.34 kB Last Modified 03/13/2020
UL/cUL; Class 1, Div 2 1.12 MB Last Modified 02/27/2019
UL/cUL; Class 1, Div 2 (Canada) 1.14 MB Last Modified 02/27/2019