MVI56-Serial Picture

Siemens 3964R Network Interface Module for ControlLogix

MVI56-S3964R

Limited Availability: Product with low inventory remaining. More Info

The MVI56 S3964R Protocol module from ProSoft Technology allows point-to-point communication between a ControlLogix processor (1756-L1, -L1Mx, L55, L6x) and a partner with 3964R communication capability.

Features and Benefits

The 3964R protocol was designed by Siemens for bi-directional data communication through a point-to-point connection. It is a peer to peer protocol with read and write access. A BCC checksum ensures the safety of the transfer.

Applications

The module is ideal in control configurations where there is a need for the ControlLogix processor to exchange data with other non-Rockwell Automation control devices in low speed applications.

The MVI56-S3964R can communicate with devices using two RS-232, RS-422 communication lines (ports). The ports operate independently from each other.

Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Local or remote rack
  • Single-slot, ControlLogix backplane compatible
  • Multiple modules can be placed in a rack up to the chassis power supply limit
  • While in 3964R with RK512 mode on PRT1 and PRT2, DB-SEND and DB-FETCH instructions can be initiated from the ControlLogix processor or received by the communications partner
  • While in 3964R without RK512 mode on PRT1 and PRT2, data can be sent from the ControlLogix processor or be received from the communications partner
  • The maximum transfer size is 512 bytes in any mode
  • Data byte swapping can be configured to adjust to a different word format
  • While in 3964R with RK512 mode on PRT1 and PRT2, evaluation of the header information DB (data block), DW (data word) and coordination bytes 9 and 10 is possible
  • Communication activity and diagnostics are available through LEDs and acknowledgment telegrams

Ladder Logic

Ladder logic programming in the ControlLogix processor is required in order to enable and support the Siemens 3964R protocol functionality. The ladder program handles the encoding/decoding of data transferred from the module as well as the initiation of protocol-specific functionality in the module. Example ladder programs are provided with the module to simplify the implementation of the module in the user application.

Hardware

Specification

Description

Backplane Current Load

800 mA @ 5.1 VDC
3 mA @ 24 VDC

Operating Temperature

32° F to 140° F (0° C to 60° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Shock

30 g Operational
50 g non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (without condensation)

LED Indicators

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Debug/Configuration port (CFG)

CFG Port (CFG)

RJ45 (DB-9M with supplied cable)
RS-232 only

Application ports (PRT1 & PRT2)

Full hardware handshaking control, providing radio, modem and multi-drop support

Software configurable communication parameters

Baud rate: 110 to 115,200 baud, depending on protocol

RS-232, 485 and 422

Parity: none, odd or even

Data bits: 5, 6, 7, or 8

Stop bits: 1 or 2

RTS on/off delay: 0 to 65535 milliseconds

App Ports (P1,P2) (Serial modules)

RJ45 (DB-9M with supplied cable)

RS-232 handshaking configurable

500 V Optical isolation from backplane

Shipped with Unit

RJ45 to DB-9M cables for each port

6-foot RS-232 configuration cable

Certifications

ATEX Letter of Conformity 79.81 kB Last Modified 05/12/2022
CB Safety 41.99 kB Last Modified 02/26/2020
Declaration of Conformity (RoHS/CE) 137.73 kB Last Modified 05/20/2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB Last Modified 07/10/2020
Korean KC Registration 616.34 kB Last Modified 03/13/2020
UL/cUL; Class 1, Div 2 1.12 MB Last Modified 02/27/2019
UL/cUL; Class 1, Div 2 (Canada) 1.14 MB Last Modified 02/27/2019
Declaration of REACH Compliance 133.82 kB Last Modified 05/20/2022