I am using a ProSoft MVI46 solution and I am getting a Fault Message that says, "Specialty I/O Module in Slot x has not responded within the time limit." What can cause this? |
Article Number: 416 | Rating: Unrated | Last Updated: Thu, Jun 16, 2011 at 6:11 AM |
This particular fault is infrequent but common on the SLC platform. Without getting into a lot of boring details, it has to do with critical, sub-millisecond timing of backplane messages. ProSoft has worked closely with Rockwell Automation to minimize to the greatest extent possible the occurrances of this fault. However, users may encounter it, from time to time. Usually, all that is need to recover from this condition is to re-boot the SLC processor by doing a power cycle of the rack. You can also sometimes clear the fault by going from RUN to PROGRAM mode and back to RUN or REM RUN. If the MVI46 module continues to cause this fault, please check for the following: 1. Be sure the BATT LED is Off. If it is On Red, it can cause this fault. To correct the problem, leave the MVI46 module in a powered-up chassis until BATT LED goes off. This could be for as little as a few minutes to as much as a few hours. If the module is left in a powered-up rack for a solid 24-hour period and the BATT LED is still on, the module must be returned to ProSoft for repair. The battery is NOT user-replacable in the field. 2. Check the Setup Jumper. Be sure it is installed on only one of the two pins and not installed to short both pins. Setup Mode is used only for updating module firmware and only when directed to do so by ProSoft Technical Support Engineers. If the jumper is installed to short both pins during normal operation, it might cause this fault. 3. In the module BIOS settings screen, there is a parameter called "Console on Port". The options for this parameter are "Enabled" and "Disabled". The factory default setting is "Disabled" and should be left this way. If you change the setting to "Enabled" and you begin to get the above fault, you will need to go back into the BIOS and set the parameter back to "Disabled." If you don't know how to get into the BIOS, then don't try. If you suspect this may be the problem, call ProSoft Technical Support for assistance in checking and/or correcting this issue. 4. Sometimes, moving the module to another slot in the chassis, preferrably closer to the SLC processor may eliminate the fault. The fault may also occur due to a hardware problem within the chassis itself, the SLC CPU, or the ProSoft module. Swapping out SLC, chassis and module may eliminate the problem. If none of these suggestions correct the problem, please contact ProSoft Technical Support for further assistance. |
Attachments (0)
There are no attachments for this article.
|
Comments
There are no comments for this article. Be the first to post a comment.
|
When using the sample ladder I get an M0/M1 file reference error in my SLC processor if the MVI46 or 3150 is not in Slot 1.
Viewed 1 times since Tue, Nov 28, 2006
Debug port connection parameters for Prosoft modules and gateways
Viewed 1 times since Tue, Nov 28, 2006
How to enable Modbus commands in MVI46-MNETC
Viewed 1 times since Wed, Sep 24, 2014
IEC-60870-5-104 Server Tutorial
Viewed 1 times since Mon, Sep 3, 2012
Where can I locate the User Manual for the MVI46-MCM
Viewed 1 times since Tue, Nov 28, 2006
Can the MVI46 or 3150 modules be placed in a remote rack?
Viewed 1 times since Tue, Nov 28, 2006
How do I deal with an unsigned integer in an SLC, PLC5, or MicroLogix processor?
Viewed 1 times since Tue, Jan 23, 2007
My MVI46 module faults the processor after cycling power to the rack.
Viewed 1 times since Tue, Nov 28, 2006
How can I store my RSLogix500 program in a M13 EEPROM installed in a ProSoft 3250-L532M SLC processor?
Viewed 1 times since Wed, Dec 3, 2008
Is there a limit to the number of ProSoft modules I can place in my SLC chassis?
Viewed 1 times since Tue, Nov 28, 2006
|