How can I store my RSLogix500 program in a M13 EEPROM installed in a ProSoft 3250-L532M SLC processor? |
Article Number: 419 | Rating: 5/5 from 1 votes | Last Updated: Wed, Mar 9, 2011 at 1:29 PM |
Before answering that question, a little history lesson will help understand the issue and the suggested solution. The ProSoft 3250-L532M SLC 5/03 RTU processor's operating system (OS) firmware is 100% compatible only with Allen-Bradley's (A-B) M11 and M12 EEPROMs. However, these EEPROMs are no longer available from A-B. If you can locate one of these via the second-hand market, you can install and use them with no problems reading or writing. The 3250-L532M is also capable of reading a program from a M13 EEPROM once the program has been stored on it; but is not able to write a program to the M13 EEPROM. The inability to write to the M13 EEPROM is a result of the older operating system revision used on the 3250-L532M not having the necessary algorithm to write to those newer EEPROMs. The M11 and M12 EEPROMs were based on 12 volt technology memory chips. When those memory chips became obsolete and no longer available to A-B, they developed the M13 EEPROM, which uses 5 volt technology memory chips. The 5 volt chips can be read by any OS version but require a different algorithm for writing to them than was used for the 12 volt chips in the M11 and M12 EEPROMs. Therefore, the 5 volt algorithm had to be added to the operating system (OS) firmware. A-B did this with the release of their Series C OS. The Series C OS is a newer OS release than the one used in the ProSoft 3250-L532M solution. Therefore, pre-Series C OS processors, like the ProSoft 5/03 RTU, can read programs from a M13 EEPROM once the program has been stored on it; but can't write a program to the M13 EEPROMs. Nor can the OS in the 5/03 RTU be upgraded to Series C. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
I am using a ProSoft MVI46 solution and I am getting a Fault Message that says, "Specialty I/O Module in Slot x has not responded within the time limit." What can cause this?
Viewed 1 times since Fri, Oct 31, 2008
When using the sample ladder I get an M0/M1 file reference error in my SLC processor if the MVI46 or 3150 is not in Slot 1.
Viewed 1 times since Tue, Nov 28, 2006
My MVI46 module faults the processor after cycling power to the rack.
Viewed 1 times since Tue, Nov 28, 2006
How to enable Modbus commands in MVI46-MNETC
Viewed 1 times since Wed, Sep 24, 2014
IEC-60870-5-104 Server Tutorial
Viewed 1 times since Mon, Sep 3, 2012
Where can I locate the User Manual for the MVI46-MCM
Viewed 1 times since Tue, Nov 28, 2006
What are the advantages of the MVI46-MCM compare to the 3150-MCM?
Viewed 1 times since Tue, Nov 28, 2006
Debug port connection parameters for Prosoft modules and gateways
Viewed 1 times since Tue, Nov 28, 2006
How do I deal with an unsigned integer in an SLC, PLC5, or MicroLogix processor?
Viewed 1 times since Tue, Jan 23, 2007
Can the MVI46 or 3150 modules be placed in a remote rack?
Viewed 1 times since Tue, Nov 28, 2006
|