How to upload a configuration file from 4xxx or 5xxx Gateway? |
Article Number: 84 | Rating: 4/5 from 1 votes | Last Updated: Fri, Jun 27, 2014 at 4:38 PM |
It is recommended to use ProSoft Configuration Builder to upload and download configuration files to 4xxx and 5xxx series gateways. ProSoft Configuration Builder is provided free of charge and can be downloaded here: http://www.prosoft-technology.com/Products/ProSoft-Software/ProSoft-Configuration-Builder Steps to upload a configuration file from a gateway: 1)Right click and select add module 2)Right click on the module and select Choose module type (select your gateway) 3)right-click and select upload from device to PC 4) To the PC connect the Null Modem Cable (Cable 15) with the Mini-Din - DB9 adapter cable (Cable 09) that came with the gateway. (The Mini-Din to DB9 cable is not the same as a Rockwell Mini-Din to db9 cable.) 5) Select the Com Port that the cables are plugged into. 6) Click Upload. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
Why does the session time out when downloading a configuration file via HyperTerminal to my 4xxx or 5xxx Series ProLinx Gateway?
Viewed 1 times since Tue, Nov 28, 2006
Can I configure my ProLinx 4xxx or 5xxx series gateway via Ethernet?
Viewed 1 times since Tue, Nov 28, 2006
Debug port connection parameters for Prosoft modules and gateways
Viewed 1 times since Tue, Nov 28, 2006
Why am I unable to communicate with Wonderware from a 4xxx or 5xxx Series gateway in a full Duplex DF1 configuration
Viewed 1 times since Tue, Nov 28, 2006
Can the FIFO buffer settings on my Windows PC COM Ports affect communications to In-Chassis modules and 5000 series gateways?
Viewed 1 times since Tue, Jul 8, 2008
Why am I unable to download a configuration file to a 4xxx or 5xxx Series gateway, and the Debug Port LED is on?
Viewed 1 times since Fri, Jun 27, 2014
Does the 4102 or 5102-MCM4-DFCM4 module have 4 Modbus ports and 4 DF1 ports (8 ports total)?
Viewed 1 times since Tue, Nov 28, 2006
Can USB be used with Prosoft Configuration Builder for Config Transfers over CIPConnect?
Viewed 1 times since Thu, Jul 16, 2015
I am trying to connect to the Debug/Configuration port using HyperTerminal on Windows Vista. How can I do this?
Viewed 1 times since Thu, Apr 9, 2009
Does ProSoft Configuration Builder run in Windows 7/8/10?
Viewed 1 times since Wed, Jun 25, 2014
|