Modbus Plus Dual Port Network Interface Module for ControlLogix

MVI56-MBP

The MVI56-MBP Modbus Plus Communication Module allows ControlLogix compatible processors to interface easily with other Modbus Plus protocol compatible devices.

The Modbus Plus module is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others).

Compatible devices include not only Modicon PLCs (which all support the Modbus Plus protocol) but also a wide assortment of end devices licensed through the ModConnect Program. The MVI56-MBP module acts as an input/output module between the Modbus Plus network and the ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the Modbus Plus network.A 4000-word register space in the module exchanges data between the processor and the Modbus Plus network.

These modules allow platforms to connect directly on Modbus Plus networks as a peer. In addition, the modules act as slaves to processors that must read/write data from the module’s memory.

Crossing all industrial boundaries, potential applications include the connection of processors to Modicon processors, and the connection of Modbus Plus speaking devices such as drives, relays, and power monitor hardware to the ControlLogix backplanes.

Features and Benefits

  • Single Slot - 1756 backplane compatible
  • Local or remote rack
  • The MVI56-MBP is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module.
  • Ladder Logic is used for data transfer between module and processor.
  • Configuration data obtained through user-defined ladder. Sample ladder file included.

Specifications

Functional Specifications

  • Communication parameters (Config port only)
    • Baud: 57,600 (fixed)
    • Parity: none (fixed)
    • Stop: 1 (fixed)
  •  Modbus Plus ports
    • Memory usage is user definable
    • Support for the storage and transfer of up to 4,000 registers across the backplane
    • 100 word reads and writes (max. allowed)
    • Supports all five levels of Modbus Plus routing
    • Software configurable parameters Node address: 1 to 64
    • Global out size: 0 to 32 words
    • Global in size: 0 to 32 words
    • Module data transfer: 0 to 4,000 words
    • Master command count: 0 to 200 commands
  • Function codes accepted (as a Slave): 1, 2, 3, 4, 5, 6, 15, 16
  • Function codes transmitted (as a Master): 3, 16

Global Data Specifications

The MBP module actively exchanges global in (32 words max. per node) and global out (32 words max.) data on the Modbus Plus network. Priority is given to these data types to provide a high speed mechanism for the transfer of control data.

Modbus Slave Mode Specifications

  • Supports broadcast commands from host
  • Communication error codes returned to ladder logic

Modbus Master Mode Specifications

  • Command list support of up to 200 commands
  • Conditional and continuous command list polling
  • Each command list entry is fully configurable for function register to/from addressing and word/bit count/word and byte swap
  • Event driven bit and register write commands (ladder logic controlled)
  • Supports sending of broadcast commands
  • Communication status error codes returned to ladder logic on a per command basis

Hardware

Specification

Description

Backplane Current Load

800 mA @ 5.1 VDC
3 mA @ 24 VDC

Operating Temperature

0° C to 60° C (32° F to 140° F )

Storage Temperature

-40° C to 85° C (-40° F to 185° F )

Shock

30 g Operational
50 g non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (non-condensing)

LED Indicators

Module Status

Backplane Transfer Status

Application Status

Serial Activity

Debug/Configuration port (CFG)

CFG Port (CFG)

RJ45 (DB-9M with supplied cable)

RS-232 only

Application ports (PRT1 & PRT2)

Modbus Plus Connector

Two DB9 Female Standard Modbus Plus connectors

Shipped with Unit

RJ45 to DB-9M adapter cable
6-foot RS-232 configuration cable

Certifications

Ex Certificate (ATEX Directive) 79.81 kB Last Modified 11/01/2012
CB Safety 41.99 kB Last Modified 11/01/2012
Declaration of Conformity (RoHS/CE) 301.57 kB Last Modified 03/04/2018
Russian GOST-R 1.23 MB Last Modified 11/01/2012
Korean KC Registration 2.46 MB Last Modified 11/01/2012
Lloyd's Register 2.13 MB Last Modified 11/01/2012
UL/cUL; Class 1, Div 2 1.12 MB Last Modified 05/20/2014
UL/cUL; Class 1, Div 2 (Canada) 1.14 MB Last Modified 05/20/2014